Your Cart
Internet cookies are used to allow personalized pages to be presented to make your visit more convenient and quick to your personal needs. Click for detailed info.

You must be a member to see the prices. If you are a member, please login. If you are not, please sign up. Becoming a member is free.

FPA-2000-PWM, Addressable Panel Kit Premium License

FPA-2000-PWM, Addressable Panel Kit Premium License
FPA-2000-PWM, Addressable Panel Kit Premium License
  • Stock Status: In Stock
  • Brand: Bosch
  • Model: FPA-2000-PWM
  • Weight: 20.00kg
  • Dimensions: 638.00mm x 440.00mm x 149.00mm
  • SKU: FPA-2000-PWM
  • HS CODE: 85371000
  • MPN: FPA-2000-PWM

Available Options

FPA-2000-PWM, Addressable Panel Kit Premium License

FPA-2000-PWM comes with 1 LSN-300A Loop card. You can expand the panel up to 4 loops. You can add up to 3 LSN-300A to your cart and increase it to 4 loops.

  • Compact modular fire panel, expandable up to 4 loops, provides customized solutions for small to medium size applications
  • High resolution display with bright colors to indicate alarms and events
  • 8" touch pad with fixed and programmable buttons, thus adaptable to the situation
  • Integrated Ethernet switch for networking and interfaces to remote services, building management and voice alarm systems
  • Adaptable to local requirements and regulations
The fire panel allows mixed operation of analog addressable and conventional technology. It supports connecting periphery in either stub or loop topologies. Analog addressable fire detectors, manual call points, signaling devices, inputs and outputs are identified and managed by the fire panel as single elements. As required by the building structure the peripherals are grouped software wise in logical zones. The compact modular fire panel comes as a kit in a housing. The functional modules can be plugged onto the rail inside the housing. The rail provides power and internal communication to the functional modules.

A wide range of functional modules is available providing different connections and functions: addressable loops, conventional zones, inputs and outputs as well as interfaces to various devices. The fire alarm panel can be equipped with six functional modules of which a maximum of four can be analog addressable loop modules. This makes the fire panel suitable for small to medium size applications.

The fire panel is available with two different types of housings:

  • Wall mount housing
  • Frame mount housing

The slim wall mount housings are for mounting directly to the wall. Frame mount housings require an additional frame between the housing and the wall.

The frame lets space for e.g. cabling, media converters, and larger batteries. Special installation kits also allow installation in 19" racks. The panel controller is the central component of the fire panel. A color display shows all messages. The touch screen is for operation of the entire system. The user-friendly interface adapts to various situations. This causes correct operation that is simple and clear as well as targeted and intuitive. Panels and keypads of the AVENAR series and of the FPA-5000 series (MPC-xxxx-B and MPC-xxxx-C) can be combined in one panel network using the Ethernet and the CAN bus interfaces. The remote keypad is for decentralized operation of the panel or of the panel network.

Integration into large-scale systems can be done by an Ethernet interface to the Bosch Hierarchy panel (UGM) or to Building Integration System (BIS). Integration into third party management systems is possible with the availability of OPC server and Software Development Kit.

A data interface enables monitoring and full control of Bosch voice alarm systems. This makes the fire panel a complete safety solution. The fire panel is configured on a laptop using the FSP-5000-RPS programming software. The programming software enables further adaptation, e.g. to country-specific requirements and regulations.

FUNCTIONS

AVENAR panel 2000 is a compact modular fire panel for small to medium size systems. It comes standard in a housing with panel controller, power supply, battery controller module and one LSN loop module. Depending on the project specific needs, the fire panel can be extended with up to four LSN 0300 A loop modules, in total six functional modules. Each loop can contain up to 254 LSN elements.

Alarm indication

All messages are shown on the display with a bright color. The displayed messages contain the following information:

  • Message type
  • Type of the triggering element
  • Description of the exact location of the triggering element
  • Logical zone and sub-address of the triggering element

18 Icon LEDs give continuous information about the operating status of the panel or the system. A red icon LED shows an alarm. A blinking yellow icon LED shows a fault. A steady yellow icon LED shows a disabled function. A green icon LED shows proper operation.

Two status LEDs, one red and one yellow, are programmable. The red one shows a self-defined alarm. The yellow one shows a self-defined fault or deactivation.

Additional annunciator modules, each with 16 red and 16 yellow LEDs are available to indicate a larger number of self-defined alarms, faults or deactivations.

Operation and processing of messages

For operating the panel, an 8 inch touch pad as input medium is put upon the display. There are 6 buttons with fixed functionality as well as 3 programmable function keys.

Examples for the assignment of the function keys:

  • Set the panel controller to day mode, set the panel controller to night mode
  • Enable detection points or outputs, disable detection points or outputs
  • Set standard sensor sensitivity, set alternative sensor sensitivity
  • Each function key has a virtual status indicator.
  • At any time, an operator with sufficient user rights can control the function keys.

Overview of evacuation zones and outputs

At any time, the operator can get a clear overview of each evacuation zone and of each output connected to the fire protection equipment. Each zone and each output is marked with a programmable text label and a clearly distinctive color reflecting the state: Green shows idle state, power is available. Red shows an activation during fire alarm condition, and fuchsia an activation without a fire alarm condition. Yellow shows a fault or disabled state. An operator with sufficient user rights is able to start the evacuation in selected zones and activate outputs connected to the fire protection equipment through the user interface.

Saving and printing messages

The history log keeps incoming alarms and events internally. The history log has a capacity to store 10000 messages. The messages can be shown on the display, and you can export the messages. Additionally, you can connect a log printer via a serial interface module for real-time printing incoming messages.

Languages

The operator can change the language of the user interface. A printed quick user guide for each language is supplied with the package. Following languages are included: English, German, Bulgarian, Croatian, Czech, Danish, Dutch, Estonian, French, Greek, Hungarian, Italian, Latvian, Lithuanian, Polish, Portuguese, Romanian, Russian, Serbian, Slovak, Slovenian, Spanish, Swedish and Turkish.

Operator management

The system can have up to 200 different registered operators. Login is permitted with a user ID and an 8- digit pin code.

There are four different authorization levels. Depending on the authorization level it is possible for the operator to do certain functions according to EN54-2.

Licenses

The panel controller is delivered with a hard coded software license. This software license is implemented during production and cannot be modified, revoked or transported. The license defines the maximum panel network size and availability of certain features and interfaces.


AVENAR panel 2000, standard license

AVENAR panel 2000, premium license

Ethernet interface to



Building management system (OPC server, BIS, FSM-5000-FSI)


UGM-2040 Hierarchy panel


Voice alarm system (Smart Safety Link)


Monitoring and control


Status overview

Simultaneous control

Individual control


Modularity (maximum number)


Slots for functional modules (max number including slots for LSN modules)

6

6

LSN modules (max number)



LSN 0300 A modules (1 slot per module)

4

4

LSN 1500 A modules

0

0

Panel redundancy



Redundant panel controller



Keypad as redundant panel controller



Network



Panel network

remote keypads

panels, remote keypads, servers

Max. number of nodes

4 (1 panel, 3 keypads)

32

Category
Category Yangın Alarm Sistemi
Fire Alarm System Specifications
Product Type Fire Alarm Panel
Panel Type Addressable
Number of Loops up to 4
Number of Connectable Detectors up to 1016

Write a review

Please login or register to review