Your Cart
Internet cookies are used to allow personalized pages to be presented to make your visit more convenient and quick to your personal needs. Click for detailed info.

You must be a member to see the prices. If you are a member, please login. If you are not, please sign up. Becoming a member is free.

FAS-420-TT1, Aspirating Smoke Detector(1 Detector)

FAS-420-TT1, Aspirating Smoke Detector(1 Detector)
FAS-420-TT1, Aspirating Smoke Detector(1 Detector)
Please Ask
FAS-420-TT1, Aspirating Smoke Detector(1 Detector)
FAS-420-TT1, Aspirating Smoke Detector(1 Detector)
FAS-420-TT1, Aspirating Smoke Detector(1 Detector)
  • Stock Status: Please Ask
  • Brand: Bosch
  • Model: FAS-420-TT1
  • Weight: 1,500.00g
  • Dimensions: 292.00mm x 200.00mm x 113.00mm
  • SKU: FAS-420-TT1
  • EAN: 8717332382491
  • HS CODE: 85319000
  • MPN: FAS-420-TT1

Available Options

FAS-420-TT1, Aspirating Smoke Detector(1 Detector)

The FAS‐420 Series Aspirating Smoke Detectors are specially designed for direct connection to the Local SecurityNetwork LSN improved version with the extended features. They are active fire detection systems for early fire detection in area and equipment monitoring, as well as for the monitoring of air conditioning units or ducts.

They have the latest detection technology. Their resistance to contamination, the temperature compensation of the sensor signals and initialization in relation to air pressure ensure reliable operation even under extreme environmental conditions.

The SL-versions with extremely quiet fan are applicable for noise sensitive areas, for example hotel rooms, hospitals and bureaus. The noise was reduced to 38 dB(A) and up to 34 dB(A) with additional sound absorber.

 

Main Features

  • Connectable to the fire panels FPA‐5000 and FPA‐1200 with the improved LSN technology
  • High deceptive alarm immunity with intelligent signal processing LOGIC·SENS
  • Innovative airflow monitoring including single-hole monitoring detects obstruction and breakage
  • Initial set-up made easy by automatic initialization
  • Easy diagnostics through flash code on the Detector Module or by using the FAS‐ASD‐DIAG diagnostic software

 

  1. Pipe system/air intake
  2. Air sampling openings
  3. Housing
  4. Detector Module incl. airflow sensor
  5. Aspiration unit
  6. Air outlet

The aspiration unit takes air samples from the monitoring area through a pipe system with defined air sampling openings and passes the samples to the Detector Module.

Depending on the response sensitivity of the used Detector Module, the Aspirating Smoke Detector triggers an alarm when the appropriate smoke density is reached. This alarm is displayed via the alarm LED on the unit and is transmitted to the fire panel.

An airflow sensor checks the connected pipe system for breakage and obstruction.

Intelligent signal processing LOGIC·SENS compares the measured smoke level with known disturbance variables and decides between alarm and deception. For the display and transmission of alarm and faults various delay times can be selected.

Each Detector Module is monitored for contamination, signal malfunction and device removal. Malfunctions and certain device states are displayed using various LED flash codes on the Detector Module's electronics PCB.

A fault message is reset via the connected fire panel. Via the Local SecurityNetwork LSN the alarm and fault messages on the unit are reset simultaneously with the detector line.

Models:

  • FAS-420-TP1    Aspirating Smoke Detector basic unit, with LED displays for operation, malfunction, and alarm, for one Detector Module, for connecting one pipe system
  • FAS-420-TP2    Aspirating Smoke Detector basic unit, with LED displays for operation, malfunction, and alarm, for two Detector Modules, for connecting two pipe systems
  • FAS-420-TT1    Aspirating Smoke Detector basic unit, with differentiated alarm and smoke level display, for one Detector Module, for connecting one pipe system
  • FAS-420-TT2    Aspirating Smoke Detector basic unit, with differentiated alarm and smoke level display, for two Detector Modules, for connecting two pipe systems

Required Detector Modules

  • FAS-420-TP1 için    DM‐TT‐50(80), DM‐TT‐10(25) veya DM‐TT‐01(05)
  • FAS-420-TP2 için    DM‐TT‐50(80), DM‐TT‐10(25) veya DM‐TT‐01(05)
  • FAS-420-TT1 için    DM‐TT‐50(80), DM‐TT‐10(25) veya DM‐TT‐01(05)
  • FAS-420-TT2 için    DM‐TT‐50(80), DM‐TT‐10(25) veya DM‐TT‐01(05)

Category
Category Fire Alarm System
Fire Alarm System Specifications
Operation Type Addressable
Product Type Detector
Detection Type Aspirating Smoke

Write a review

Please login or register to review

In the pre-order system;


We obtain your products from the manufacturer / distributor in the fastest way and send them to your address.

  • Products in stock are sent to you directly by the distributor company distributor in Turkey the same day.
  • Products in the stock of foreign distributors / producers are shipped within 4 weeks.
If the product is not available, your payment will be refunded.