FAP-425-DOT-R, Addressable Optical Smoke + Thermal Detector
- Stock Status: In Stock
- Brand: Bosch
- Model: FAP-425-DOT-R
- Weight: 80.00g
- Dimensions: 99.50mm x 99.50mm x 52.00mm
- SKU: FAP-425-DOT-R
- EAN: 8717332906574
- HS CODE: 853110000000
- MPN: FAP-425-DOT-R
FAP-425-DOT-R, Addressable Optical Smoke + Thermal Detector
Analog addressable detector with two optical sensors, one thermal sensor, manually and automatically addressable.
- Detection Area: 120 m²
- Max. Installation Height: 16m
AVENAR detector 4000 is a new range of automatic fire detectors featuring a superb accuracy and swiftness in detection. The versions with two optical sensors (dual‐optical) are able to detect the lightest smoke. The range includes versions with rotaries, manually and automatically addressable, and versions without rotaries for automatic address setting.
Optical sensor (smoke sensor)
The optical sensor uses the scattered-light method. An LED transmits light to the measuring chamber, where it is absorbed by the labyrinth structure. In the event of a fire, smoke enters the measuring chamber and the smoke particles scatter the light from the LED. The amount of light hitting the photo diode is converted into a proportional electrical signal.
The dual-optical versions use two optical sensors with different wavelengths. The Dual-Ray technology works with an infrared and a blue LED so that lightest smoke is detected fast and reliably (TF1 and TF9 detection).
Thermal sensor (temperature sensor)
A thermistor in a resistance network is used as a thermal sensor from which an analog-digital converter measures the temperature-dependent voltage at regular intervals.
Depending on the specified detector class, the temperature sensor triggers the alarm status when the maximum temperature of 54 °C or 69 °C is exceeded(thermal maximum), or if the temperature rises by a defined amount within a specified time (thermal differential).
Chemical sensor (CO gas sensor)
The main function of the gas sensor is to detect carbon monoxide (CO) generated as a result of a fire, but it will also detect hydrogen (H) and nitrous monoxide (NO). The sensor signal value is proportional to the concentration of gas. The gas sensor delivers additional information to effectively suppress deceptive values.
Since the service life of the gas sensor is limited, the C sensor shuts down automatically after a maximum of 6 years of operation. The detector will then still operate as a multi-sensor detector with dual-optical and thermal sensor. It is recommended to exchange the detector immediately in order to keep the higher detection reliability of the version with C sensor.
Model Code |
Sensor |
Number of Sensors |
Detection Area |
Max. Installation Height |
Address Setting |
Detector Base Model Code |
Color Code |
Dimensions(without Base) |
Weight(With Packaging) |
FAP-425-O |
Smoke |
One Optical |
120m² |
16m |
Automatically |
MS-400 |
No Marking |
Ø 99,5 x 52 mm |
115gr |
FAH-425-T-R |
Heat |
One Thermal |
40m² |
7,5m |
Manually / Automatically |
MS-400 |
Red Loop |
Ø 99,5 x 52 mm |
120gr |
FAP-425-O-R |
Smoke |
One Optical |
120m² |
16m |
Manually / Automatically |
MS-400 |
No Marking |
Ø 99,5 x 52 mm |
115gr |
FAP-425-OT |
Smoke, Heat |
One Optical & One Thermal |
120m² |
16m |
Automatically |
MS-400 |
Black Loop |
Ø 99,5 x 52 mm |
115gr |
FAP-425-OT-R |
Smoke, Heat |
One Optical & One Thermal |
120m² |
16m |
Manually / Automatically |
MS-400 |
Black Loop |
Ø 99,5 x 52 mm |
120gr |
FAP-425-DO-R |
Smoke |
Two Optical |
120m² |
16m |
Manually / Automatically |
MS-400 |
2 Grey Loop |
Ø 99,5 x 52 mm |
120gr |
FAP-425-DOT-R |
Smoke, Heat |
Two Optical & One Thermal |
120m² |
16m |
Manually / Automatically |
MS-400 |
2 Grey Loop |
Ø 99,5 x 52 mm |
120gr |
FAP-425-DOTC-R |
Smoke, Heat, Carbon Monoxide |
Two Optical, One Thermal, One Chemical |
120m² |
16m |
Manually / Automatically |
MS-400 |
2 Yellow Loop |
Ø 99,5 x 52 mm |
130gr |
Category | |
Category | Fire Alarm System |
Fire Alarm System Specifications | |
Operation Type | Addressable |
Product Type | Detector |
Detection Type | Smoke Heat |